Sign In | Join Free | My himfr.com
Home > Heating And Cooling Heat Pump >

24kw Air Source Hvac System Heat Pump Heat And Cool 500L Air Energy Heat Pumps

    Buy cheap 24kw Air Source Hvac System Heat Pump Heat And Cool 500L Air Energy Heat Pumps from wholesalers
     
    Buy cheap 24kw Air Source Hvac System Heat Pump Heat And Cool 500L Air Energy Heat Pumps from wholesalers
    • Buy cheap 24kw Air Source Hvac System Heat Pump Heat And Cool 500L Air Energy Heat Pumps from wholesalers

    24kw Air Source Hvac System Heat Pump Heat And Cool 500L Air Energy Heat Pumps

    Ask Lasest Price
    Brand Name : LN
    Model Number : DKFXRS-9I/CY
    Certification : CE ISO CCC
    Price : Negotiable
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 80000pcs/year
    Delivery Time : 1-30 working days
    • Product Details
    • Company Profile

    24kw Air Source Hvac System Heat Pump Heat And Cool 500L Air Energy Heat Pumps

    Instant Hot Water Heater Provided Air Source Exchange Heat Pump Air To Water HVAC system


    An energy storage interconnected heat pump defrosting device with slow frost formation includes an energy storage interconnected heat pump body, the energy storage interconnected heat pump body is provided with a heat pump chamber inside, and the left side of the energy storage interconnected heat pump body is fixedly connected with an intake pipe, The right side of the energy storage interconnected heat pump body is fixedly connected with a water outlet, the right side of the energy storage interconnected heat pump body is fixedly connected with a water inlet, and a water storage tank is fixedly installed inside the heat pump chamber. The utility model effectively removes the frost layer inside the energy storage interconnected heat pump body, so that the hot air inside the energy storage interconnected heat pump body enters the defrosting pipe from the air inlet, and leaves the defrosting pipe through the air outlet, so that the hot air is directed to the evaporator The outer frost layer is removed to achieve the defrosting effect, thereby reducing the forming efficiency of the frost layer, and achieving the advantages of slow frost formation, which effectively solves the problem that the existing energy storage interconnected heat pump cannot effectively remove the frost layer. The use of energy storage interconnected heat pumps.

    Strength of Leomon Instant Hot Water Heater Provided Air Source Exchange Heat Pump Air To Water HVAC System
    Low noise:
    Full DC inverter floor heating air conditioner adopts inverter compressor dedicated for heat pump, and the noise is less than 50 decibels
    Wifi remote control
    The full DC frequency conversion floor heating air-conditioner adopts the linkage control of the internal and external units. The main unit and the thermostat have 485 remote, which can be remotely controlled. If there is an area air conditioner and floor heating, it can be viewed and turned off remotely
    HVAC system design
    The full DC frequency conversion floor heating air conditioner adopts a secondary system design, using the unit circulating pump and the end circulating pump respectively. The unit circulating pump and the end circulating pump adopt self-frequency conversion control. When the use area is small, the water pump runs at low frequency, which can greatly reduce the water pump. Energy loss.
    Heat recovery technology
    In summer, air-source heat pump triple-supply unit can adopt heat recovery method to produce hot water for free when the air-conditioning host is cooling

    Company brief introduction
    Over 20 years production experience, thanks to R&D hard and smart working, company is authorized over 400 patents, products quality play a lead role in HVAC system field
    Over 20% sales volume are invested on improving products research and company service imporovement, we are happy to say"We cannot promise that equipment won't break, that software won't fail, or that we will always be perfect. What we can promise is that if something goes wrong, we will rise to the occasion, take action, and help resolve the issue, and the most important is we have abilidty to solve! ."

    Some technical paremeters for Instant Hot Water Heater Provided Air Source Exchange Heat Pump Air To Water HVAC System

    Spec.KRY-24IIKRY-48IIKRY-96II
    Rated heating capacity(A24/26oC)24kw48kw96kw
    Rated power(kW)4.79.318.5
    COP5.15.165.41
    Rated heating capacityA20/26oC21kw44 kw90kw
    Rated power(kW)4.58.617.5
    COP4.665.115.14
    Cooling Capacity(kW)11.323.740
    Consumed Power(kW)4.99.118.2
    EER2.32.62.2
    Rated voltage(Hz)380V 3N-50HZ380V 3N-50HZ380V 3N-50HZ
    The compressorZW61KA-TFP-52E(one sets )ZW61KA-TFP-52E(two sets )ZW61KA-TFP-52E(four sets )
    Fan Quantity124
    Fan Quantity(W)370×1370×2370×4
    Fan speed(rpm)850850850
    Maximum input power(kW)61224
    Maximum current(A)244280
    Water flownWh71332
    noise dB(A)<65<68<69
    Anti-shock levelIII
    waterproof levelIPV4IPV4IPV4
    Unit size (mm)780x820x17001550x780x17001550x1550x1700
    Unit Weight(kg)260380760
    Rated heating conditions: outdoor dry/wet bulb temperature is 24°C/19°C, hot water inlet temperature is 26°C, outlet water temperature is 28°C;
    Rated heating conditions: outdoor dry/wet bulb temperature is 20°C/15°C, hot water inlet temperature is 26°C, outlet water is 28°C;
    Rated Cooling conditions: outdoor dry/wet bulb temperature is 35°C, COOL water inlet temperature is 30°C, outlet water is 28°C.

    Compressor Info

    ModelRefrigerantHeating
    (
    kw)
    Input power
    (
    KW)
    Current
    (
    A)
    Large running current
    (
    A)
    Weight
    (
    kg)
    ZW61KA-TFP-52ER2221.863.129.614.430

    Quality 24kw Air Source Hvac System Heat Pump Heat And Cool 500L Air Energy Heat Pumps for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Maanshan Leonon Energy Saving Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)