Sign In | Join Free | My himfr.com
Home > Heating And Cooling Heat Pump >

DC Inverter CO2 Air Source Heat Pump Cooling System 1KW 50Hz

    Buy cheap DC Inverter CO2 Air Source Heat Pump Cooling System 1KW 50Hz from wholesalers
     
    Buy cheap DC Inverter CO2 Air Source Heat Pump Cooling System 1KW 50Hz from wholesalers
    • Buy cheap DC Inverter CO2 Air Source Heat Pump Cooling System 1KW 50Hz from wholesalers

    DC Inverter CO2 Air Source Heat Pump Cooling System 1KW 50Hz

    Ask Lasest Price
    Brand Name : LN
    Model Number : SFYRS-60II
    Certification : CE ISO CCC
    Price : Negotiable
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 80000pcs/year
    Delivery Time : 1-30 working days
    • Product Details
    • Company Profile

    DC Inverter CO2 Air Source Heat Pump Cooling System 1KW 50Hz

    Features of DC Inverter CO2(R744) Air Source Heat Pump Hot Water And Heating System

    The carbon dioxide heat pump unit uses the natural working fluid CO2 (R744) as the refrigerant. Through the CO2 transcritical cycle, the low-grade heat source in nature is transformed into the energy-saving equipment with high-grade heat energy that can be used.
    The CO2 heat pump unit provides users with a high-efficiency and energy-saving hot water solution, one-time heating, without circulating heating, and the maximum outlet water temperature can reach 90°C. The equipment investment is small, the operating cost is low, and the energy-saving effect is significant.
    Products are widely used in hotels and restaurants, hospitals, pharmaceuticals, industrial waste heat recovery, oil extraction and other fields. A new way for mankind to save fossil fuels, reduce greenhouse gas emissions, improve energy utilization, and reduce environmental pollution.

    Refrigerant characteristics
    CO2 refrigerant [R744] has excellent environmental performance, zero ozone depletion potential (ODP=0), minimal greenhouse effect potential (GWP=1), non-toxic, non-flammable, and good chemical stability. The unit is safe to use, no smoke, dust, combustion, and waste discharge.

    Unit series
    Heat source classification: water source type, air source type
    Refrigerant: CO2
    Heating method: one-time heating
    Heating capacity: 1kW~1MW
    Coefficient of performance: 4.6 (under nominal working conditions)
    Maximum water outlet temperature: 90℃
    Power supply: 380V/50Hz CO2

    Company introduction:

    Leomon technology rnjoy rich experience in supplying air source heat pumps, supply its own brand and OEM for customers worldwide.

    Products series: air source heat pumps for household, water heater, swimming pool heat pumps, heating system

    Keep working at technical and commercial ability, company is athorized over 300 patents, norminated factory for supplying heat pumps.

    Quality Control: DC Inverter CO2(R744) Air Source Heat Pump Hot Water And Heating System

    100% products inspection before delivery, 3 phrases test to guarantee right quality and quantity before delivery

    Whole lifespan after sale service

    Some specification of DC Inverter CO2(R744) Air Source Heat Pump Hot Water And Heating System

    NameCarbon Dioxide heat pump unit
    Model numberSFYRS-60II
    Power supply380V/50Hz
    Heating modeOne-time formula
    Performance parameterTest StandardStandard working conditionLow temperature conditionHigh temperature condition
    Heat capacity (kW)64.455.453.8
    Electricity Consumption (kW)13.71316.3
    COP4.74.33.3
    Hot Water flow (m³/h)1.381.030.61
    Maximum current34A
    Weight1000kg
    Contour dimensionLength1500*Wide1200*High1800
    Design pressureHigh pressure side:14.5MPa,Low pressure side6MPa
    CompressorSemi-closed reciprocating
    Refrigerant nameR744 ( CO2 )
    Water heat exchangerCopper bushing changer
    Heat source side exchangerPlate heat exchanger
    Feed pump0.75kW
    Operation PanelColor touch screen
    Control SystemSiemens
    Water connectionFeed water inletDN40Internal thread
    Hot Water InletDN20Internal thread
    Insulated water inletDN20Internal thread
    Heat connectionHot Water InletDN40Internal thread
    Heat source water outletDN32Internal thread
    SCOPE of useFeed water temperature5~29℃
    Effluent temperature55~90°℃
    Maximum flow2.5m³/h
    Ambient temperature’-10~43℃
    NotesStandard working conditionInlet temperature: 15 °C, outlet temperature: 55 °C, heat source water inlet temperature: 15 °C
    Low temperature conditionThe inlet temperature is 9 °C, outlet temperature is 55 °C, and the inlet temperature of heat source water is 10 °C
    High temperature conditionThe inlet temperature is 15 °C, the outlet temperature is 90 °C, and the inlet temperature of heat source water is 15 °C


    Quality DC Inverter CO2 Air Source Heat Pump Cooling System 1KW 50Hz for sale