    Brand Name : LN
    Model Number : KCHR-15II/BP (Out of the wind)
    Certification : CE ISO CCC
    Price : Negotiable
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 80000pcs/year
    Delivery Time : 1-30 working days
    • Product Details
    • Company Profile

    Commercial 300L Dc Inverter Heat Pump Water Heater 24A

    Features of Watermark Water Tank 300l Air Source Heat Pump Hot Water Heater

    The air source heat pump hot water system consists of an air source heat pump unit, a hot water storage tank, a water pump, and pipelines. Hot water is circulated through the system to heat the water in the hot water storage tank, and then supplied to the user from the hot storage tank. The air source heat pump system can produce hot water alone, and is often used in solar energy systems as an auxiliary heat source for the system. System features The air source heat pump hot water system has changed the traditional heating element and fuel direct heating method, thereby eliminating potential safety hazards such as electricity leakage and air leakage, and has more excellent safety performance. The air source heat pump hot water system has a large water output and a stable water temperature, ensuring a sufficient supply of hot water for 24 hours, and high comfort. Using the air source heat pump hot water system, the power consumption is only a quarter of the electric heating, the energy saving effect is obvious, and the operating cost is very low. The air source heat pump hot water system just transfers the heat from the surrounding air to the water, completely achieving zero emission, green and environmentally friendly modular design, easy to install, and the principle of the system is that the compressor compresses the return low pressure refrigerant.

    Modular control system reduces energy loss

    The host provides moderate energy requirements according to the end, reducing unnecessary energy loss.


    The main machine does not contain electricity auxiliary heat, energy saving

    The host machine of all series products of Leomon heat pumps does not contain electricity and auxiliary heat, which saves unnecessary operation cost.

    Watermark Water Tank 300l Air Source Heat Pump Hot Water Heater

    Closed refrigerant system, safe and stable

    Fluorine refrigerant system leakage points, easy to lead to frequent leakage of refrigerant, reduce equipment performance and service life. Leomon heat pumps water machine system adhere to the international standard of closed refrigerant design, the unit in high or low temperature conditions also has excellent heat transfer efficiency.

    Company introduction
    20 years of professional heat pump system technology excellence
    We give full play to the advantages of scientific and technical personnel, and constantly overcome the technical bottlenecks in the field of air energy water heater. We have obtained 120 invention patents, more than 350 other patents, and participated in the preparation of 25 national standards.

    Products series: swimming pool/spa air source heat pumps
    All in one triple multifunctional heat pumps: heating(Central heating ,floor heating, radient heating)+cooling+ hot water or seperate function
    Heat pumps water heater
    as leader for air source heat pumps, decades experience,authorized over100 patents, leader for swimming pool air source heat pumps and other pumps, member for editing heat pumps field standards, strong and professional technical team

    Our strong and professional technical and marketing team ready to make best service!

    Pre order(Inquiry progress):

    Check with customer about usage, request specifications, enviroment and other request

    Make details proposal/offer to customer

    Order Processing

    • Machine installed and tested by QA engineers.

    • Ensure all the products we provide are qualified and new. The working life of the main engine is 15 years.

    • Construct and install the heat pump according to national relevant policies strictly and ensure high quality delivery on time.

    • Test and debug the equipments strictly to ensure the safety and stability.

    • During the delivery, provide comprehensive and professional technical training on instructions and maintenance to customers

    • After sale service

    • 2 years warranty

    • Feedback and solution will be provided within 1 working day

    • Free technical support!

    • Technical paremeters for Watermark Water Tank 300l Air Source Heat Pump Hot Water Heater

    • ItemKCHR-13I/BP
      Side wind)
      Rated voltage220V~50Hz
      Cooling and heatingNominal cooling
      capacity
      13kW(3kW-15kW)
      Nominal cooling power
      consumption
      4.6KW
      Nominal cooling(COP)2.82
      IPLV4.13
      Nominal heating capacity14kW(3.5kW-16kW)
      Nominal heating power
      consumption
      4.5KW
      HeatingNominal heating capacity10.5KW
      Nominal heating
      power consumption
      2.65KW
      Nominal heating(COP)3.96
      Maximum operating current33A
      Maximum power consumption6.6KW
      Rated water flow2.24m²/h
      Refrigerant/charge volumeR410A/4000g
      noise≤56dB(A)
      Water resistance≤15kPa
      Maximum working pressure on low
      pressure/high pressure side
      4.5Mpa/0.15Mpa
      Allowable working pressure on
      suction/exhaust side
      4.5Mpa/0.15Mpa
      Anti-shock levelI
      waterproof levelIPX4
      Unit size (l× w × h)1030×410×1390(mm)
      (Cold and warm) Caliber of inlet
      and outlet
      DN32
      (Hot water) CaliberDN25
      Application area100㎡

    • Nominal refrigeration conditions: ambient dry bulb 35℃, outlet temperature 7℃. Nominal heating conditions: ambient dry bulb 7℃, ambient wet bulb 6℃,outlet temperature 45℃
    • Nominal hot water production conditions: ambient dry bulb 20℃, ambient wet bulb 15℃, initial water temperature 15℃, end water temperature 55℃.