Sign In | Join Free | My himfr.com
Home > Commercial Air Source Heat Pump >

DKFXRS-9I/CY Radiant Heat Pumps DC Inverter Air To Water Chiller

    Buy cheap DKFXRS-9I/CY Radiant Heat Pumps DC Inverter Air To Water Chiller from wholesalers
     
    Buy cheap DKFXRS-9I/CY Radiant Heat Pumps DC Inverter Air To Water Chiller from wholesalers
    • Buy cheap DKFXRS-9I/CY Radiant Heat Pumps DC Inverter Air To Water Chiller from wholesalers

    DKFXRS-9I/CY Radiant Heat Pumps DC Inverter Air To Water Chiller

    Ask Lasest Price
    Brand Name : LN
    Model Number : DKFXRS-9I/CY
    Certification : CE ISO CCC
    Price : Negotiable
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 80000pcs/year
    Delivery Time : 1-30 working days
    • Product Details
    • Company Profile

    DKFXRS-9I/CY Radiant Heat Pumps DC Inverter Air To Water Chiller

    THE MOST ENERGY EFFICIENT AND INNOVATIVE SOLUTION OF GETTING DOMESTIC HEATING & COOLING & HOT WATER BY USING AIR SOURCE HEAT PUMP
    Features of Radiant Heat Pumps Air To Water Chiller

    The energy-saving control method of the floor radiant heating system of the variable-frequency heat pump water heater is characterized by the steps of the control method: the control system establishes the calculated temperature Tgj of the floor water supply and the ambient temperature of the room temperature according to the performance of the variable-frequency heat pump water heater and the heat load characteristics of the heating room. The functional formula between Tw; the control system establishes a functional formula between the room calculated air temperature Tnj and the ambient temperature Tw based on the thermal comfort of the human body; the control system adjusts the conversion according to the difference between the actual water supply temperature Tgs and the supply calculated temperature Tgj The compressor speed of the heat pump water heater makes the actual calculated water temperature Tgs and the calculated water temperature Tgj converge; the control system adjusts the opening of the three-way proportional control valve according to the difference between the actual room air temperature Tns and the room calculated air temperature Tnj, Make the room actual air temperature Tns and the room calculated air temperature Tnj converge. It has the advantages of higher energy efficiency of heat pump water heater, energy saving in operation and better thermal comfort of human body, etc.

    CORE TECHNOLOGIES of Radiant Heat Pumps Air To Water Chiller
    DC INVERTER COMPRESSOR Twin-Cylinder Rotary DC Inverter Compressor
    INVERTER TECHNOLOGY: 40Hz-120Hz Wide Frequency operation range
    SMART CONTROL SYSTEM:Hitachi DC Inverter Control System

    The kinetic energy of subdivision, the water tank is free of washing for lifespan

    Closed refrigerant system, safe and stable

    Gold - aluminum condensation process rapid frost

    Ship cabin positioning monitoring system, accurate detection of water temperature


    Air source heat pumps series and application: Water heaters heat pump, swimming pool heat pumps, spa heaters, Radient/underfloor heating,cooling and hot water muldtifunction all in one heat pump

    Application: swimming pool, household hot water, schools, restarants, Sauna, spas, day care center`````


    We have various specifications and types of Radiant Heat Pumps Air To Water Chiller Air To Water Heat Pump For House Heating to offer, welcome to contact for furthder details

    Triple supply parameters Cooling, heating and hot water functions
    ItemKCHR-8I/BP
    Side wind
    KCHR-13I/BP
    Side wind)
    KCHR-15I/BP
    Side wind
    KCHR-15II/BP
    (Out of the wind)
    Rated voltage220V~50Hz220V~50Hz220V~50Hz380V 3N~50Hz
    Cooling and heatingNominal cooling
    capacity
    7.8kW(2kW-9kW)13kW(3kW-15kW)14.5kW(4kW-16.5kW)14.5kW(4kW-16.5kW)
    Nominal cooling power
    consumption
    2.77KW4.6KW5.27KW5.27KW
    Nominal cooling(COP)2.812.822.752.75
    IPLV4.114.134.024.02
    Nominal heating capacity8.4kW(2.5kW-9.6kW)14kW(3.5kW-16kW)17kW(4.3kW-18.5kW)17kW(2.5kW-18.5kW)
    Nominal heating power
    consumption
    2.78KW4.5KW5.6KW5.6KW
    HeatingNominal heating capacity6.8KW10.5KW13KW13KW
    Nominal heating
    power consumption
    1.75KW2.65KW3.3KW3.3KW
    Nominal heating(COP)3.883.963.933.93
    Maximum operating current20A33A41A21A
    Maximum power consumption4KW6.6KW7.9KW7.9KW
    Rated water flow1.34m²/h2.24m²/h2.5m²/h2.5m²/h
    Refrigerant/charge volumeR410A/1750gR410A/4000gR410A/4000gR410A/4800g
    noise≤54dB(A)≤56dB(A)≤57dB(A)≤58dB(A)
    Water resistance≤14kPa≤15kPa≤21kPa≤21kPa
    Maximum working pressure on low
    pressure/high pressure side
    4.5Mpa/0.15Mpa4.5Mpa/0.15Mpa4.5Mpa/0.15Mpa4.5Mpa/0.15Mpa
    Allowable working pressure on
    suction/exhaust side
    4.5Mpa/0.15Mpa4.5Mpa/0.15Mpa4.5Mpa/0.15Mpa4.5Mpa/0.15Mpa
    Anti-shock levelIIII
    waterproof levelIPX4IPX4IPX4IPX4
    Unit size (l× w × h)1030×410×865(mm)1030×410×1390(mm)1030×410×1390(mm)820×780×1700(mm)
    (Cold and warm) Caliber of inlet
    and outlet
    DN25DN32DN32DN32
    (Hot water) CaliberDN20DN25DN25DN25
    Application area60㎡100㎡110㎡110㎡
    Some projects of Radiant Heat Pumps Air To Water Chiller
    Quality DKFXRS-9I/CY Radiant Heat Pumps DC Inverter Air To Water Chiller for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Maanshan Leonon Energy Saving Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)