Sign In | Join Free | My himfr.com
Home > High COP Heat Pump >

Cascade High COP Heat Pump Unit 150Kw for R410A R134a Refrigerant

    Buy cheap Cascade High COP Heat Pump Unit 150Kw for R410A R134a Refrigerant from wholesalers
     
    Buy cheap Cascade High COP Heat Pump Unit 150Kw for R410A R134a Refrigerant from wholesalers
    • Buy cheap Cascade High COP Heat Pump Unit 150Kw for R410A R134a Refrigerant from wholesalers
    • Buy cheap Cascade High COP Heat Pump Unit 150Kw for R410A R134a Refrigerant from wholesalers
    • Buy cheap Cascade High COP Heat Pump Unit 150Kw for R410A R134a Refrigerant from wholesalers
    • Buy cheap Cascade High COP Heat Pump Unit 150Kw for R410A R134a Refrigerant from wholesalers
    • Buy cheap Cascade High COP Heat Pump Unit 150Kw for R410A R134a Refrigerant from wholesalers
    • Buy cheap Cascade High COP Heat Pump Unit 150Kw for R410A R134a Refrigerant from wholesalers

    Cascade High COP Heat Pump Unit 150Kw for R410A R134a Refrigerant

    Ask Lasest Price
    Brand Name : LN
    Model Number : 150kw
    Certification : CE ISO CCC
    Price : 1000
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 450000pcs/year
    Delivery Time : 1-30 working days
    • Product Details
    • Company Profile

    Cascade High COP Heat Pump Unit 150Kw for R410A R134a Refrigerant

    Principle of 150 kw Ultra-low temperature variable frequency cascade high temperature heat pump unit
    The basic operating principle of the cascaded high temperature air source heat pump unit is based on the reverse
    Carnot cycle principle. The working fluid system is divided into a low temperature level circulation system and
    a high temperature level circulation system. The low-pressure gas is compressed into a medium-temperature and
    medium-pressure gas by the low-temperature stage compressor, and enters the intermediate heat exchanger to
    condense into a liquid state to release heat. The liquid working medium is decompressed and expanded by the
    expansion valve and then returns to the fin In the heat exchanger, the evaporation heat is absorbed again to
    complete a low temperature cycle; at the same time, the liquid working medium of the high temperature machine
    absorbs the heat transmitted by the low temperature stage in the intermediate heat exchanger and evaporates
    into a medium temperature and low pressure gas, and the low pressure gas is compressed by the low pressure
    stage compressor. The medium-temperature and medium-pressure gas is compressed into a high-temperature and
    high-pressure gas by a high-temperature compressor, which is condensed into a liquid state in a heat exchanger
    to release heat to produce high-temperature hot water. In the intermediate heat exchanger, the evaporation heat
    is absorbed again to complete a low temperature cycle; through the reciprocating cycle, the effect of producing
    high temperature hot water at a low temperature ambient temperature is achieved.

    The ultra-low temperature variable frequency cascade high temperature heat pump unit adopts the form of R410A low temperature stage and R134a high temperature stage system. Heat exchange for making hot water or heating. The ultra-low temperature cascade high temperature heat pump unit adopts DC frequency conversion technology, which has high heating energy efficiency. Temperature can be stable heating 75 ° C.

    Performance characteristics of 150 kw Ultra-low temperature variable frequency cascade high temperature heat pump unit
    1. Full DC frequency conversion control technology: The frequency conversion control technology based on variable working conditions can automatically adjust the load; the heating capacity is less attenuated, and the heating capacity is increased by 30% compared with the conventional single-system heat pump;
    2. High temperature of water supply: high temperature special compressor is adopted, rated supply/return water temperature is 70°C/60°C, and water supply temperature is up to 75°C;
    3. Good low temperature performance: normal heating 70°C at -30°C ambient temperature, heating COP at -12°C/-14°C ambient temperature not less than 1.8, heating COP at -25"C ambient temperature Not less than 1.5;
    4. Wide range of applications: the water supply temperature is 40°C~70°C, the applicable ambient temperature is -35°C~25°C, and it is suitable for a variety of terminal forms, and can be used in most cold areas in northern my country;
    5. Easy installation of the project: the overall modular structure design is adopted, the structure is compact, the operation noise is low, the floor space is small, and the installation cost is low;
    6. Remote cloud monitoring: The whole system is equipped with a remote monitoring system, which can check the operating status and operating parameters of the unit in real time, check fault alarms and operate remotely, and realize 24-hour unmanned management.

    SpecKFXRS-25II/GWKFXRS-52II/GWKFXRS-102II/GWKFXRS-150II/GW
    voltage380V 3N~50Hz380V 3N~50Hz380V 3N~50Hz380V 3N~50Hz
    Nominal heating capacity(hot water)25kW52kW102kW150kW
    Nominal heating capacity input power8kW16.5kW33kW48kW
    Low temperature heating capacity (hot water)18kW36.5kW72kW110kW
    Low temperature heating input power6kW12kW24kW36kW
    Maximum input power13kW26kW52kW78kW
    Maximum operating current35A70A140A210A
    Nominal heating capacity ( heating)21kW42kW84kW125kW
    Nominal heating input power7kW14kW28kW42kW
    Low temperature heating (heating)18kW36kW79kW108kW
    Low temperature heating input power6kW12kW24kW36kW
    Rated water flow3.5m³/h7m³/h14m³/h21m³/h
    Refrigerant name/injection amountR410A/R134a(5500g/4200g)R410A/R134a(5500g/4200g)*2R410A/R134a(5500g/4200g)*4R410A/R134a(5500g/4200g)*6
    water side resistance≤55kPa≤65kPa≤85kPa≤95kPa
    noise≤62dB(A)≤68dB(A)≤72dB(A)≤76dB(A)
    Allowable working pressure on exhaust
    /suction side
    4.5MPa/0.15MPa4.5MPa/0.15MPa4.5MPa/0.15MPa4.5MPa/0.15MPa
    High pressure/low pressure side maximum allowable pressure4.5MPa4.5MPa4.5MPa4.5MPa
    Maximum working pressure of heat exchanger4.5MPa4.5MPa4.5MPa4.5MPa
    size (L*W*H)mm780*820*17801550*780*1780mm1570*1550*1850mm2360*1550*1850mm
    Weight160kg318kg630kg950kg
    Anti-shock levelI
    waterproof levelIPX4IPX4IPX4IPX4
    ConnectionDN32(outside)DN40(outside)DN54(flange)DN65(flange)
    Unit Price usd/set360767251311519680
    Heating conditions: (hot water):
    The ambient dry bulb is 20°C, the ambient wet bulb is 15°C, the initial water temperature is 15°C, and the final water temperature is 75°C.
    Environmental dry bulb -7°C, ambient wet bulb -8°C, initial water temperature 6°C, and end water temperature 75°C.
    Terminal universal heating unit
    Heating condition: (heating)
    The ambient dry bulb is 7°C, the ambient wet bulb is 6°C, and the effluent water temperature is 75°C.
    Environmental dry bulb -7°C, ambient wet bulb -8°C, effluent water temperature 75°C.


































    Quality Cascade High COP Heat Pump Unit 150Kw for R410A R134a Refrigerant for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Maanshan Leonon Energy Saving Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)