Sign In | Join Free | My himfr.com |
|
Ask Lasest Price | |
Brand Name : | LN |
Model Number : | SJKRS-05I/C |
Certification : | CE ISO CCC ROHS |
Price : | Negotiable |
Payment Terms : | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability : | 80000pcs/yearCryogenic Operation/Long-Range Control /R22 R410A/Residential and Commercial Buildings Air Source Heat Pump |
Delivery Time : | 1-30 working days |
Description of DORIN INVERTER CO2(R744) Heat Pump Systems Carbon dioxide high temperature heat pump air source and water source
The carbon dioxide transcritical heat pump unit has a significant energy saving effect in waste heat recovery. Through the excellent characteristics of carbon dioxide supercritical, only a small amount of electricity is required to produce high-temperature hot water. In the cold area of 100 to 20 degrees in the north, the waste heat of the air can be absorbed. In the supercritical area of carbon dioxide, the gas heat exchanger can still efficiently produce high-temperature hot water above 60 °C.
CO2 Heat Pump Working Principle
The working principle of CO2Heat Pump is that the refrigerant
absorbs the heat in the air(or water), compressed by the compressor
to become a high-temperature and high-pressure gas to be
discharged. The high-temperature and high-pressure refrigerant gas
is cooled by the gas cooler and transfers the heat to the water
then realize the heating function.
Working Temperature of Carbon Dioxide Heat Pump:-43-43℃Outlet Water
Temperature:35-100℃COP:3.2-7.0
Performance of Zew Zealand 8kw Residential CO2 Heat Pump System for Combined Space Heating and Hot Water Heating
Ultra-low temperature working conditions: ambient temperature
DB-10-C, water inlet temperature 9°C;
Defrost condition: ambient temperature DB2°C/WB1°C, water inlet
temperature 9°C; low temperature condition: ambient temperature
DB7°C/WB6°C, water inlet temperature 9°C; standard working
condition: ambient temperature DB20°C /WB15°C, inlet water
temperature 15°C; high temperature working condition: ambient
temperature DB38°C/WB23°C, inlet water temperature 29°C.
Installation Notes:
1. The spacing around the installation must not be less than Im;
2. The pipelines other than the heat pump should be protected from
frost and heating elements can be installed;
3. Heat insulation and protection measures should be taken for the
pipelines for hot water circulation to prevent heat loss.
HP | A/mm | B/mm | C/mm |
7.5 | 1450 | 950 | 1450 |
10 | 1600 | 950 | 1500 |
15 | 1850 | 1150 | 1900 |
20 | 2050 | 1150 | 1950 |
30 | 2670 | 1410 | 2150 |
40 | 2290 | 2270 | 1980 |
Application Diagram Pressure-bearing water tank
Zew Zealand 8kw Residential CO2 Heat Pump System for Combined Space Heating and Hot Water Heating
System Diagram Smart Control System
Zew Zealand 8kw Residential CO2 Heat Pump System for Combined Space Heating and Hot Water Heating
CO2 heat pump hot water unit specification list Zew Zealand 8kw Residential CO2 Heat Pump System for Combined Space Heating and Hot Water Heating | ||||||||
Model | SJKRS-05I/C | SJKRS-28II/C | SJKRS-36II/C | SJKRS-55II/C | SJKRS-73II/C | SJKRS-106II/C | SJKRS-160II/C | |
Specification | 2HP | 7.5HP | 10HP | 15HP | 20HP | 30HP | 45HP | |
Power supply | 230V/1N/50Hz | 380V/3N/50Hz | ||||||
Heating Method | Direct heating / circulating | |||||||
Nominal working condition | ( kw)heating capacity | 7.45 | 28.1 | 37.7 | 56.1 | 74.1 | 108.6 | 158.7 |
( kw) Input power | 1.61 | 6.1 | 8.2 | 12.2 | 16.1 | 23.6 | 34.5 | |
COP | 4.6 | 4.6 | 4.6 | 4.6 | 4.6 | 4.6 | 4.6 | |
( m³/h) Heating water flow | 0.11 | 0.6 | 0.81 | 1.21 | 1.62 | 2.33 | 3.41 | |
High temperature working conditions | (kw)heating capacity | 5.58 | 23.9 | 28.5 | 51.5 | 59.5 | 89 | 131.5 |
( kw)Input power | 1.73 | 7.5 | 8.9 | 16.1 | 18.6 | 27.8 | 41.1 | |
COP | 3.2 | 3.2 | 3.2 | 3.2 | 3.2 | 3.2 | 3.2 | |
( m³/h) Heating water flow | 0.07 | 0.27 | 0.33 | 0.59 | 0.68 | 1.02 | 1.51 | |
Low temperature working conditions | (kw)heating capacity | 4.3 | 15.7 | 19.1 | 31.8 | 38.9 | 59.3 | 90 |
( kw)Input power | 1.59 | 5.8 | 7.1 | 11.8 | 14.4 | 21.9 | 33.3 | |
COP | 2.7 | 2.7 | 2.7 | 2.7 | 2.7 | 2.7 | 2.7 | |
(m³/h) Heating water flow | 0.07 | 0.28 | 0.34 | 0.56 | 0.68 | 1.04 | 1.52 | |
Parts information | Water pipe interface size | DN15 | DN20 | DN25 | DN32 | |||
Water heat exchanger | Plate or tube heat exchanger | |||||||
Air heat exchanger | Copper tube aluminum fins | |||||||
Compressor type | Double rotary | Semi-closed reciprocating type | ||||||
Operation panel | Color touch screen | |||||||
Maximum outlet temperature | 85℃ | 90℃ | ||||||
Refrigerant | R744(CO2) | |||||||
Design pressur(MPa) | 15MPa(HP)/8MPa(LP) | |||||||
Dimensions (L,W,H mm) | 750*390*1245 | 1450*950*1450 | 1600*950*1500 | 1850*1150*1900 | 2050*1150*1950 | 2670*1410*2150 | 2070x2150x2245 | |
( dB) Noise | ≤44 | ≤56 | ≤59 | ≤62 | ≤67 | ≤70 | ≤70 | |
( kg) Weight | 83 | 550 | 660 | 780 | 860 | 1180 | 1360 | |
Feedwatertemperature(℃) | 5~40 | |||||||
( Feed water pressure MPa) | 0.05~0.4 | |||||||
Water Outlet temperature (℃) | 55~85 | 55~90 | ||||||
Maximum flow | 0.24 | 1.2 | 1.5 | 2.4 | 3.2 | 4.9 | 6.5 | |
Ambient temperature (℃) | -25~43 |
System schematic diagram
Leomon ) Energy Saving Technology Co, Ltd. focus on design and
produce the CO, Heat Pumps, Steam Engine Heat Pumps and Closed
Dryers, also provide various energy solutions.
We has a complete industrial chain of CO, Heat Pump Series, Steam
Engine Heat Pump, and Closed Drver Series. The products include
CO,Water Heating Heat Pump, CO, Heating Heat Pump, CO, Heat Air
Blower,UItra-low Temperature CO, Cascade Heat Pump, and CO, Water
Source Heat Pump, CO, Domestic Hot Water+Heating+Solar 3-in-1 Heat
Pump, CO, Swimming Pool Heat Pump, Multi-functional CO, Swimming
Pool Constant Temperature and Humidity Heat Pump, High Temperature
Steam Engine Heat Pump (120℃), Closed Dryer and so on. Among them,
the export volume for CO, Heat Pumps is on the top. Carbonated
Water Source Heat Pumps are widely used in the south. Our 3-in-1
Heat Pump for Domestic Hot Water+Heating+Solar Energy is warmly
welcome in the market especially in European Market. What's more,
the High-temperature Steam Engine Heat Pump (120°C) has become a
perfect substitute for the boiler.
![]() |