    Brand Name : LN
    Model Number : SJKRS-05I/C
    Certification : CE ISO CCC ROHS
    Price : Negotiable
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 80000pcs/yearCryogenic Operation/Long-Range Control /R22 R410A/Residential and Commercial Buildings Air Source Heat Pump
    Delivery Time : 1-30 working days
    • Product Details
    • Company Profile

    106kw Air Source Heat Pump R744 CO2 Outlet Of 90 Degree

    106kw air source heat pump R744(CO2) outlet of 90 degree

    Description of 106kw air source heat pump R744(CO2) outlet of 90 degree

    The carbon dioxide transcritical heat pump unit has a significant energy saving effect in waste heat recovery. Through the excellent characteristics of carbon dioxide supercritical, only a small amount of electricity is required to produce high-temperature hot water. In the cold area of ​​100 to 20 degrees in the north, the waste heat of the air can be absorbed. In the supercritical area of ​​carbon dioxide, the gas heat exchanger can still efficiently produce high-temperature hot water above 60 °C.

    Carbon dioxide high temperature heat pump
    Carbon dioxide is a natural working fluid, with high thermal conductivity and specific heat capacity, which helps to obtain high heat transfer coefficient; low dynamic viscosity can reduce the pressure drop of working fluid in the tube. The high vapor density helps to improve the mass flow rate of the working fluid, the density ratio (the density ratio represents the difference between the properties of the gas and the liquid) is small, which is beneficial to the distribution of the working fluid, and the surface tension is small, which can improve the boiling in the evaporator heat transfer intensity of the zone. The gas density is high, and the heating capacity per unit volume is large, which is about 5 times that of R22, which can reduce the size of pipes and compressors, making the system lighter, compact and small in size. The pressure ratio of the compressor (the ratio of the condensing pressure and the evaporating pressure of the working fluid) is low, the compression process can be closer to isentropic compression and the efficiency is improved. Wide range of sources and low prices.
    The process of carbon dioxide transcritical refrigeration cycle is slightly different from that of ordinary vapor compression refrigeration cycle. The suction pressure of the compressor is lower than the critical pressure, and the evaporation temperature is also lower than the critical temperature. The endothermic process of the cycle is still carried out under subcritical conditions. The heat exchange process relies on latent heat to complete. However, the exhaust pressure of the compressor is above the critical pressure, and no condensate is produced during the heat release process of the working medium. The high-pressure heat exchanger is no longer called a condenser, but a gas cooler. The traditional concept of condensation temperature has been lost. Meaning, the heat exchange process relies on sensible heat to complete.


    Performance of 106kw air source heat pump R744(CO2) outlet of 90 degree

    Ultra-low temperature working conditions: ambient temperature DB-10-C, water inlet temperature 9°C;
    Defrost condition: ambient temperature DB2°C/WB1°C, water inlet temperature 9°C; low temperature condition: ambient temperature DB7°C/WB6°C, water inlet temperature 9°C; standard working condition: ambient temperature DB20°C /WB15°C, inlet water temperature 15°C; high temperature working condition: ambient temperature DB38°C/WB23°C, inlet water temperature 29°C.
    Installation Notes:
    1. The spacing around the installation must not be less than Im;
    2. The pipelines other than the heat pump should be protected from frost and heating elements can be installed;
    3. Heat insulation and protection measures should be taken for the pipelines for hot water circulation to prevent heat loss.

    HPA/mmB/mmC/mm
    7.514509501450
    1016009501500
    15185011501900
    20205011501950
    30267014102150
    40229022701980

    Application Diagram Pressure-bearing water tank

    106kw air source heat pump R744(CO2) outlet of 90 degree

    System Diagram Smart Control System

    106kw air source heat pump R744(CO2) outlet of 90 degree


    CO2 heat pump hot water unit specification list

    106kw air source heat pump R744(CO2) outlet of 90 degree

    ModelSJKRS-05I/CSJKRS-28II/CSJKRS-36II/CSJKRS-55II/CSJKRS-73II/CSJKRS-106II/CSJKRS-160II/C
    Specification2HP7.5HP10HP15HP20HP30HP45HP
    Power supply230V/1N/50Hz380V/3N/50Hz
    Heating MethodDirect heating / circulating
    Nominal working condition( kw)heating capacity7.4528.137.756.174.1108.6158.7
    ( kw)
    Input power
    1.616.18.212.216.123.634.5
    COP4.64.64.64.64.64.64.6
    ( m³/h)
    Heating water flow
    0.110.60.811.211.622.333.41
    High temperature working conditions(kw)heating capacity5.5823.928.551.559.589131.5
    ( kw)Input power1.737.58.916.118.627.841.1
    COP3.23.23.23.23.23.23.2
    ( m³/h)
    Heating water flow
    0.070.270.330.590.681.021.51
    Low temperature working conditions(kw)heating capacity4.315.719.131.838.959.390
    ( kw)Input power1.595.87.111.814.421.933.3
    COP2.72.72.72.72.72.72.7
    (m³/h)
    Heating water flow
    0.070.280.340.560.681.041.52
    Parts informationWater pipe interface sizeDN15DN20DN25DN32
    Water heat exchangerPlate or tube heat exchanger
    Air heat exchangerCopper tube aluminum fins
    Compressor typeDouble rotarySemi-closed reciprocating type
    Operation panelColor touch screen
    Maximum outlet temperature85℃90℃
    RefrigerantR744(CO2)
    Design pressur(MPa)15MPa(HP)/8MPa(LP)
    Dimensions (L,W,H mm)750*390*12451450*950*14501600*950*15001850*1150*19002050*1150*19502670*1410*21502070x2150x2245
    ( dB) Noise≤44≤56≤59≤62≤67≤70≤70
    ( kg) Weight8355066078086011801360
    Feedwatertemperature(℃)5~40
    ( Feed water pressure MPa)0.05~0.4
    Water Outlet temperature (℃)55~8555~90
    Maximum flow0.241.21.52.43.24.96.5
    Ambient temperature (℃)-25~43

    System schematic diagram



    Quality 106kw Air Source Heat Pump R744 CO2 Outlet Of 90 Degree for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Maanshan Leonon Energy Saving Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)