Sign In | Join Free | My himfr.com
Home > Co2 Heat Pump >

R744 CO2 Air Source Heat Pump Water Heater Residential 90 Degree With Dorin Compressor

    Buy cheap R744 CO2 Air Source Heat Pump Water Heater Residential 90 Degree With Dorin Compressor from wholesalers
     
    Buy cheap R744 CO2 Air Source Heat Pump Water Heater Residential 90 Degree With Dorin Compressor from wholesalers
    • Buy cheap R744 CO2 Air Source Heat Pump Water Heater Residential 90 Degree With Dorin Compressor from wholesalers
    • Buy cheap R744 CO2 Air Source Heat Pump Water Heater Residential 90 Degree With Dorin Compressor from wholesalers
    • Buy cheap R744 CO2 Air Source Heat Pump Water Heater Residential 90 Degree With Dorin Compressor from wholesalers
    • Buy cheap R744 CO2 Air Source Heat Pump Water Heater Residential 90 Degree With Dorin Compressor from wholesalers
    • Buy cheap R744 CO2 Air Source Heat Pump Water Heater Residential 90 Degree With Dorin Compressor from wholesalers
    • Buy cheap R744 CO2 Air Source Heat Pump Water Heater Residential 90 Degree With Dorin Compressor from wholesalers

    R744 CO2 Air Source Heat Pump Water Heater Residential 90 Degree With Dorin Compressor

    Ask Lasest Price
    Brand Name : LN
    Model Number : SJKRS-05I/C
    Certification : CE ISO CCC ROHS
    Price : Negotiable
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 80000pcs/yearCryogenic Operation/Long-Range Control /R22 R410A/Residential and Commercial Buildings Air Source Heat Pump
    Delivery Time : 1-30 working days
    • Product Details
    • Company Profile

    R744 CO2 Air Source Heat Pump Water Heater Residential 90 Degree With Dorin Compressor

    R744 CO2 Air Source Heat Pump Water Heater For Residential Heating 7.45kw Output Of 90 Degree With Dorin Compressor

    Description of R744 CO2 Air Source Heat Pump Water Heater for Residential Heating 7.45kw output of 90 degree with dorin compressor

    The compressor sucks low-temperature and low-pressure gaseous carbon dioxide refrigerant from the evaporator, and compresses the carbon dioxide refrigerant into a high-temperature and high-pressure supercritical fluid through work. The high-temperature and high-pressure supercritical fluid enters the gas cooler to exchange heat with water, and is cooled in the gas cooler. The high-pressure fluid releases a lot of heat, and the water absorbs the heat released and the temperature continues to rise. After the high-pressure fluid is throttled and depressurized by the expansion valve, it absorbs heat from the surrounding air and evaporates into low-pressure gas through the action of the fan in the evaporator, and is sucked into the compressor to be compressed, and the cycle is repeated to produce hot water. Features Natural environmental protection refrigerant: ODP is 0, GWP is 1, no pollution to the environment, non-toxic, non-flammable Excellent high-temperature heating performance: the highest water output can reach above 90℃ Excellent low temperature performance: at -20°C ambient temperature, 90°C high temperature hot water can still be produced High efficiency: the heating performance COP can reach 4.5, and when the hot water is produced at low temperature, the COP is still above 2.0 Wide range of application: it can work normally in the ambient temperature range of -20℃~43℃, suitable for our production of domestic or industrial hot water


    Performance of R744 CO2 Air Source Heat Pump Water Heater for Residential Heating 7.45kw output of 90 degree with dorin compressor


    Ultra-low temperature working conditions: ambient temperature DB-10-C, water inlet temperature 9°C;
    Defrost condition: ambient temperature DB2°C/WB1°C, water inlet temperature 9°C; low temperature condition: ambient temperature DB7°C/WB6°C, water inlet temperature 9°C; standard working condition: ambient temperature DB20°C /WB15°C, inlet water temperature 15°C; high temperature working condition: ambient temperature DB38°C/WB23°C, inlet water temperature 29°C.
    Installation Notes:
    1. The spacing around the installation must not be less than Im;
    2. The pipelines other than the heat pump should be protected from frost and heating elements can be installed;
    3. Heat insulation and protection measures should be taken for the pipelines for hot water circulation to prevent heat loss.

    HPA/mmB/mmC/mm
    7.514509501450
    1016009501500
    15185011501900
    20205011501950
    30267014102150
    40229022701980

    Application Diagram Pressure-bearing water tank

    R744 CO2 Air Source Heat Pump Water Heater for Residential Heating 7.45kw output of 90 degree with dorin compressor

    System Diagram Smart Control System

    R744 CO2 Air Source Heat Pump Water Heater for Residential Heating 7.45kw output of 90 degree with dorin compressor


    CO2 heat pump hot water unit specification list

    R744 CO2 Air Source Heat Pump Water Heater for Residential Heating 7.45kw output of 90 degree with dorin compressor

    ModelSJKRS-05I/CSJKRS-28II/CSJKRS-36II/CSJKRS-55II/CSJKRS-73II/CSJKRS-106II/CSJKRS-160II/C
    Specification2HP7.5HP10HP15HP20HP30HP45HP
    Power supply230V/1N/50Hz380V/3N/50Hz
    Heating MethodDirect heating / circulating
    Nominal working condition( kw)heating capacity7.4528.137.756.174.1108.6158.7
    ( kw)
    Input power
    1.616.18.212.216.123.634.5
    COP4.64.64.64.64.64.64.6
    ( m³/h)
    Heating water flow
    0.110.60.811.211.622.333.41
    High temperature working conditions(kw)heating capacity5.5823.928.551.559.589131.5
    ( kw)Input power1.737.58.916.118.627.841.1
    COP3.23.23.23.23.23.23.2
    ( m³/h)
    Heating water flow
    0.070.270.330.590.681.021.51
    Low temperature working conditions(kw)heating capacity4.315.719.131.838.959.390
    ( kw)Input power1.595.87.111.814.421.933.3
    COP2.72.72.72.72.72.72.7
    (m³/h)
    Heating water flow
    0.070.280.340.560.681.041.52
    Parts informationWater pipe interface sizeDN15DN20DN25DN32
    Water heat exchangerPlate or tube heat exchanger
    Air heat exchangerCopper tube aluminum fins
    Compressor typeDouble rotarySemi-closed reciprocating type
    Operation panelColor touch screen
    Maximum outlet temperature85℃90℃
    RefrigerantR744(CO2)
    Design pressur(MPa)15MPa(HP)/8MPa(LP)
    Dimensions (L,W,H mm)750*390*12451450*950*14501600*950*15001850*1150*19002050*1150*19502670*1410*21502070x2150x2245
    ( dB) Noise≤44≤56≤59≤62≤67≤70≤70
    ( kg) Weight8355066078086011801360
    Feedwatertemperature(℃)5~40
    ( Feed water pressure MPa)0.05~0.4
    Water Outlet temperature (℃)55~8555~90
    Maximum flow0.241.21.52.43.24.96.5
    Ambient temperature (℃)-25~43

    System schematic diagram



    Quality R744 CO2 Air Source Heat Pump Water Heater Residential 90 Degree With Dorin Compressor for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Maanshan Leonon Energy Saving Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)