Sign In | Join Free | My himfr.com
Home > Co2 Heat Pump >

Commercial REVERE CO₂ R744 Air To Water Heat Pump 40kw

    Buy cheap Commercial REVERE CO₂ R744 Air To Water Heat Pump 40kw from wholesalers
     
    Buy cheap Commercial REVERE CO₂ R744 Air To Water Heat Pump 40kw from wholesalers
    • Buy cheap Commercial REVERE CO₂ R744 Air To Water Heat Pump 40kw from wholesalers

    Commercial REVERE CO₂ R744 Air To Water Heat Pump 40kw

    Ask Lasest Price
    Brand Name : LN
    Model Number : SJKRS-8 II/C
    Certification : CE ISO CCC ROHS
    Price : Negotiable
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 80000pcs/year
    Delivery Time : 1-30 working days
    • Product Details
    • Company Profile

    Commercial REVERE CO₂ R744 Air To Water Heat Pump 40kw

    Strength of Commercial REVERE CO₂ R744 Air to Water Heat Pump 40kw


    A carbon dioxide heat pump device equipped with a high-density phase change heat storage unit, including a carbon dioxide heat pump, the carbon dioxide heat pump water inlet pipe is connected to the first electric three-way valve, the bypass pipe of the first electric three-way valve is connected to the carbon dioxide heat pump water outlet pipe three-way, the carbon dioxide heat pump The water outlet pipe is connected to the second electric three-way valve after the three-way, the bypass pipe of the second electric three-way valve is connected to the water inlet pipe of the high-density phase change heat storage unit, and the water outlet pipe of the high-density phase change heat storage unit is connected to the heat pump outlet. On the water pipe three-way, the electric three-way valve is controlled by the control unit; the device of the utility model can use the high-density phase change heat storage unit, when the outdoor temperature is high, while supplying heat to the system and storing the excess heat generated by the heat pump; When the outdoor temperature is very low, the heat pump is turned off and the stored heat is released for the system to use, and the electric auxiliary heating system is cancelled accordingly. Through the control of the control unit, the working performance coefficient of the carbon dioxide heat pump is maximized and the system power configuration capacity is reduced.
    Microwave drying and sterilization equipment for carbon dioxide heat pump enthalpy increase, including wetting system, material conveying system, microwave drying and sterilizing system, carbon dioxide heat pump enthalpy increasing system and gas purification system, the wetting system is used to wet the material to be treated and convey the material The system is used to transport the materials to be processed into the microwave drying and sterilizing system to be dried and sterilized by microwaves and then discharged. The moist and hot gas generated during the drying and sterilization process is cooled and dehumidified by the carbon dioxide heat pump enthalpy increasing system, and then emptied after being purified by the gas purification system. , the heat generated by the microwave generator is cooled by the carbon dioxide heat pump enthalpy increase system, and the carbon dioxide heat pump enthalpy increase system recovers the heat generated by the microwave generator and the heat of the wet and hot exhaust gas to preheat the spray water and the materials to be treated. The equipment has high drying and sterilization efficiency and good effect, utilizes the enthalpy increasing system to realize the cascade utilization of waste heat and the recycling of water resources, has low operation cost and no environmental pollution.


    Commercial REVERE CO₂ R744 Air to Water Heat Pump 40kw


    Unit typeSJKRS-28 II/CSJKRS-36II/CSJKRS-55 II/CSJKRS-73 I/CSJKRS-106 ICSJKRS-I60II /C
    Specifications7.5HP10HP15HP20HP30HP40HP
    Power supplyThree-phase five-wire380V/50Hz
    Heating modeDirect heat/cycle type
    Standard working conditionHeating capacity( kw )27.536.755.172.810.6.5155.1
    Input Power(kW)6.18.213.716.123.634.5
    COP4.54.54.54.54.54.5
    Hot Water flow(m³/h)0.590.791.181.562.293.33
    High temperature conditionHeating capacity kw )23.928.551.559.58913.1.5
    Input Power(kW)7.58.916.118.627.841.1
    COP3.23.23.23.23.23.2
    Hot Water flow(m³/h)0.270.330.590.681.021.51
    Low temperature conditionHeating capacity( kw )17.321.434.841.562.294.5
    Input Power(kW)6.27.612.414.822.233.8
    COP2.82.82.82.82.82.8
    Hot Water flow(m³/h)0.320.40.650.781.161.77
    Component InformationSize of water pipe jointDN20DN25DN32DN40
    Water heat exchangerPlate or sleeve heat exchanger
    Air Heat ExchangerAluminum Fin for copper tube
    compressor typeSemi-closed reciprocating
    Operation PanelColor touch screen
    Maximum outlet temperature(℃)90℃
    RefrigerantsR744 (CO2 )
    Design pressure(MPa)High side 15, low side 8
    Dimensions (length, width and height mm)1450x950x14501600x950x15001850x1150x19002050x1150x19502670x1410x21502290x2270x1980
    Noise (dB)565962677070
    Weight(kg)5506607808601180221360
    SCOPE of useFeed water temperature(℃)5~ 40
    Feed water pressure0.05~ 0.4
    Effluent temperature(℃)55~ 90
    Maximum flow1.21.52.43.24.96.5
    Ambient temperature(℃)’-20~43