Sign In | Join Free | My himfr.com
Home > Co2 Heat Pump >

Commercial High Temperature R744 CO2 Heat Pump For House Heating And Cooling

    Buy cheap Commercial High Temperature R744 CO2 Heat Pump For House Heating And Cooling from wholesalers
     
    Buy cheap Commercial High Temperature R744 CO2 Heat Pump For House Heating And Cooling from wholesalers
    • Buy cheap Commercial High Temperature R744 CO2 Heat Pump For House Heating And Cooling from wholesalers
    • Buy cheap Commercial High Temperature R744 CO2 Heat Pump For House Heating And Cooling from wholesalers
    • Buy cheap Commercial High Temperature R744 CO2 Heat Pump For House Heating And Cooling from wholesalers
    • Buy cheap Commercial High Temperature R744 CO2 Heat Pump For House Heating And Cooling from wholesalers

    Commercial High Temperature R744 CO2 Heat Pump For House Heating And Cooling

    Ask Lasest Price
    Brand Name : LN
    Model Number : SJKRS-106 IC
    Certification : CE ISO CCC ROHS
    Price : Negotiable
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 80000pcs/year
    Delivery Time : 1-30 working days
    • Product Details
    • Company Profile

    Commercial High Temperature R744 CO2 Heat Pump For House Heating And Cooling

    Commercial and Industrial High Temperature R744 CO2 air source Heat Pump house heating and cooling water heater

    Commercial and Industrial Heat Pumps: CO2 Models Producing Hot Water

    • Transcritical carbon dioxide (CO2) industrial heat pumps are widely used for commercial and industrial applications in Japan. Mayekawa Manufacturing Company (MYCOM) offers commercial/industrial water heating EcoCute CO2 heat pumps with ratings up to 90 kW. This water-source CO2 heat pump water heater (HPWH) can supply 5,800 gallons per day of water at 194°F. This equipment typically costs 25% to 35% more than a boiler for water heating. This technology can be very useful for generating water hot enough for radiant floor heating and many industrial processes. For example, CO2 industrial heat pumps can extract the heat from fresh milk prior to refrigeration and use it to generate hot water for washing. These units require compressors that operate between 600 to 1,700 pounds per square inch gauge (psig). The heat pump Coefficient of Performance (COP) is not negatively impacted from high-pressure operation because the compressors operate at a low pressure ratio. MYCOM has obtained Underwriters Laboratories (UL) listings for their industrial heat pump products so, unlike the residential-scale version of this technology (E3TNW #389 Carbon-Dioxide Heat Pump Water Heaters)
    • The benefits of Commercial and Industrial High Temperature R744 CO2 air source Heat Pump house heating and cooling water heater include:

    • Carbon Dioxide is a natural, environmentally friendly alternative to traditional refrigerants.
    • Effective refrigeration with simultaneous heat production to a high-temperature level.
    • Effective heat recovery using industrial waste heat sources and wastewater.
    • Reduction of CO2 pollutant emissions through oil and gas savings.
    • Highly cost-effective – short payback period.
    • Premium quality, designed and produced in Germany in line with ISO 9001:2008.
    • Plant-side quality inspections such as pressure strength tests, leak tests and electrical tests are certified.
    • State-of-the-art control technology including remote monitoring.
    • Compact design.
    • Commercial and Industrial High Temperature R744 CO2 air source Heat Pump house heating and cooling water heater specification
    Unit typeSJKRS-28 II/CSJKRS-36II/CSJKRS-55 II/CSJKRS-73 I/CSJKRS-106 ICSJKRS-I60II /C
    Specifications7.5HP10HP15HP20HP30HP40HP
    Power supplyThree-phase five-wire380V/50Hz
    Heating modeDirect heat/cycle type
    Standard working conditionHeating capacity( kw )27.536.755.172.810.6.5155.1
    Input Power(kW)6.18.213.716.123.634.5
    COP4.54.54.54.54.54.5
    Hot Water flow(m³/h)0.590.791.181.562.293.33
    High temperature conditionHeating capacity kw )23.928.551.559.58913.1.5
    Input Power(kW)7.58.916.118.627.841.1
    COP3.23.23.23.23.23.2
    Hot Water flow(m³/h)0.270.330.590.681.021.51
    Low temperature conditionHeating capacity( kw )17.321.434.841.562.294.5
    Input Power(kW)6.27.612.414.822.233.8
    COP2.82.82.82.82.82.8
    Hot Water flow(m³/h)0.320.40.650.781.161.77
    Component InformationSize of water pipe jointDN20DN25DN32DN40
    Water heat exchangerPlate or sleeve heat exchanger
    Air Heat ExchangerAluminum Fin for copper tube
    compressor typeSemi-closed reciprocating
    Operation PanelColor touch screen
    Maximum outlet temperature(℃)90℃
    RefrigerantsR744 (CO2 )
    Design pressure(MPa)High side 15, low side 8
    Dimensions (length, width and height mm)1450x950x14501600x950x15001850x1150x19002050x1150x19502670x1410x21502290x2270x1980
    Noise (dB)565962677070
    Weight(kg)5506607808601180221360
    SCOPE of useFeed water temperature(℃)5~ 40
    Feed water pressure0.05~ 0.4
    Effluent temperature(℃)55~ 90
    Maximum flow1.21.52.43.24.96.5
    Ambient temperature(℃)’-20~43


    Quality Commercial High Temperature R744 CO2 Heat Pump For House Heating And Cooling for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Maanshan Leonon Energy Saving Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)